This is a working overview of REV-ERB agonist, written for readers who want more than a one-paragraph summary but less than a textbook.
Reviewed 2026-08-01. Anything still debated is marked as such rather than presented as settled.
Several misconceptions surround SR9009. It is often described as a SARM, a steroid, or an exercise pill, but its known target is the REV-ERB receptor family. Rodent studies have examined exercise capacity and metabolic markers, yet human outcomes remain unproven. Oral bioavailability appears low in animals, and human pharmacokinetics are not well characterized. Online products may contain impurities or different compounds, so identity and purity testing are important for research use.
Analytical chemists detect SR9009 with liquid chromatography-tandem mass spectrometry, commonly abbreviated LC-MS/MS. Sample preparation may involve protein precipitation, liquid-liquid extraction, or solid-phase extraction before analysis. Laboratories can target the parent compound or its metabolites, depending on the matrix and the purpose of testing. Anti-doping methods require sensitive and specific assays because concentrations in biological samples can be low. Reference standards and validated methods are essential for reliable identification and quantification.
Analytical identification and purity assessment often use high-performance liquid chromatography with ultraviolet detection or mass spectrometry. Liquid chromatography–tandem mass spectrometry is used to detect and quantify SR9009 in biological matrices, including urine and blood, for anti-doping or pharmacokinetic studies. Nuclear magnetic resonance spectroscopy can confirm molecular structure. Stability depends on form and storage: the solid is generally more stable than solutions, and repeated freeze–thaw cycles may degrade samples. Purity is typically reported as a percentage from a certificate of analysis.
Regulatory treatment of SR9009 varies by country and context. It is not approved as a therapeutic drug by agencies such as the United States Food and Drug Administration or the European Medicines Agency. Sports authorities list it as a prohibited substance; the World Anti-Doping Agency classifies it among hormone and metabolic modulators. Legal status for personal possession or sale differs across jurisdictions, and some countries may restrict it under analog or research chemical laws. Buyers who seek verified material often rely on independent laboratory testing because online product labels may not match contents.
| Property | Value | Notes |
|---|---|---|
| Regulatory status | Not approved for human use | Research-use-only status in many markets |
| WADA status | Prohibited in sport | Generally listed as a non-approved substance |
| Detection technique | LC-MS/MS | Common for urine and blood analysis |
| Common alias | Stenabolic | Informal market nickname, not a pharmacopoeial name |
| Purity check | HPLC or LC-UV | Independent certificate of analysis is typical |
SR9009 is a synthetic small molecule studied as an agonist of the nuclear receptors REV-ERBα and REV-ERBβ. These receptors help regulate circadian rhythms and metabolic gene expression. In laboratory experiments, SR9009 binds these receptors and alters transcription of genes involved in lipid handling, glucose metabolism, and mitochondrial function. It is not a naturally occurring compound and has no approved therapeutic use. Research interest stems from its ability to modify energy metabolism in cells and animal models.
In rodent studies, SR9009 has been reported to increase mitochondrial content in skeletal muscle and improve exercise endurance under some conditions. These findings led to popular descriptions such as an exercise mimetic, although that term oversimplifies the biology. Effects vary by dose, timing, tissue, and model. The compound's influence on circadian pathways means that time of administration can matter in experiments. Whether similar metabolic changes occur in humans remains largely unexplored in controlled published trials.
REV-ERB proteins typically suppress gene expression by recruiting corepressor complexes to DNA response elements. SR9009 binds these receptors and strengthens that repressive action in cell-based assays. Studies in rodents have reported changes in lipid handling, mitochondrial function, and exercise capacity after treatment. Such findings are often cited as evidence for metabolic effects, but species differences and limited pharmacokinetic data make direct translation to humans uncertain. Researchers continue to examine which effects are robust and which depend on specific experimental conditions.
SR9009 is frequently discussed alongside other REV-ERB ligands, including synthetic agonists and natural heme-related molecules. Its selectivity for REV-ERB over related nuclear receptors has been measured in binding and reporter assays, though off-target activity at higher concentrations is possible. The compound is prohibited in sport by the World Anti-Doping Agency, and it is not approved for any medical use in major jurisdictions. Products sold online may be labeled as research chemicals, and their identity and purity are not guaranteed by regulatory review.
SR9009 is a synthetic small molecule that acts on the nuclear receptors REV-ERBα and REV-ERBβ. These receptors are part of the circadian clock machinery and normally repress transcription of certain target genes. In laboratory research, SR9009 is used as a chemical tool to study how REV-ERB activity influences metabolism, inflammation, and daily biological rhythms. The compound is not an approved medicine, and its effects in humans remain largely uncharacterized. It is often described as an investigational agent rather than a therapeutic product.
Handling recommendations for SR9009 in a laboratory setting include storing the solid at low temperature, protected from light and moisture. The compound is often dissolved in dimethyl sulfoxide or ethanol for experiments. Solutions should be prepared with appropriate personal protective equipment and disposed of according to local rules. Stability data for long-term storage are limited, so stock solutions are typically kept cold and used within defined periods. Records of preparation date and concentration support reproducibility.
SR9009 is not approved as a medicine by major regulatory agencies. It is commonly sold as a research chemical, a category that may fall outside customary drug approval and quality rules. In sports, the World Anti-Doping Agency lists SR9009 as a prohibited substance. Athletes who use it can face sanctions if it is detected in a sample. Legal status varies by country, and importation may be restricted. Enforcement practices differ across borders.
Detection of SR9009 in biological samples usually employs liquid chromatography coupled with tandem mass spectrometry. This method can identify the parent compound and sometimes metabolites in urine or blood. Because exposure can be low and clearance may be rapid, sample timing and limits of detection matter. Laboratories validate assays for sensitivity and specificity. Results are interpreted alongside chain-of-custody and quality-control records. Urine is the common matrix for anti-doping analysis, while blood may be used in research settings.
Storage conditions for research-grade SR9009 generally involve a freezer at approximately minus twenty degrees Celsius, sometimes lower for long-term preservation. Containers should remain tightly closed and protected from light. Desiccants may be used to limit moisture uptake. Solutions are often stored in aliquots to avoid repeated warming and cooling. Stability data for the compound under various conditions are limited, so laboratories typically follow supplier recommendations and verify performance through periodic analytical checks rather than assuming indefinite stability.
Identity and purity testing for SR9009 commonly uses liquid chromatography coupled with tandem mass spectrometry. This method separates the compound from matrix components and detects it by mass-to-charge transitions, providing sensitive and specific confirmation. Nuclear magnetic resonance spectroscopy can support structural identification, while high-performance liquid chromatography with ultraviolet detection may estimate purity. Because online products labeled as SR9009 may contain other substances or no active compound at all, independent verification is important in research settings. Certificates of analysis are useful but not a substitute for in-house testing.
=== Synthesis === The chemical synthesis of LSD has been described. It is commonly synthesized by reacting diethylamine with an activated form of lysergic acid. Activating reagents include phosphoryl chloride and peptide coupling reagents. Lysergic acid is made by alkaline hydrolysis of lysergamides like ergotamine, a substance usually derived from the ergot fungus on agar plate. Lysergic acid can also be produced synthetically, although these processes are not used in clandestine manufacture due to their low yields and high complexity. Albert Hofmann synthesized LSD in the following manner: (1) hydrazinolysis of ergotamine into D- and L-isolysergic acid hydrazide, (2) separation of the enantiomers with di-(p-toluyl)-D-tartaric acid to get D-isolysergic acid hydrazide, (3) enantiomerization into D-lysergic acid hydrazide, (4) substitution with HNO2 to D-lysergic acid azide and (5) finally substitution with diethylamine to form D-lysergic acid diethylamide. The precursor for LSD, lysergic acid, has been produced by GMO baker's yeast.
== Applications == Fourier-transform ion cyclotron resonance (FTICR) mass spectrometry is a high-resolution technique that can be used to determine masses with high accuracy. Many applications of FTICR-MS use this mass accuracy to help determine the composition of molecules based on accurate mass. This is possible due to the mass defect of the elements. FTICR-MS is able to achieve higher levels of mass accuracy than other forms of mass spectrometer, in part, because a superconducting magnet is much more stable than radio-frequency (RF) voltage. Another place that FTICR-MS is useful is in dealing with complex mixtures, such as biomass or waste liquefaction products, since the resolution (narrow peak width) allows the signals of two ions with similar mass-to-charge ratios (m/z) to be detected as distinct ions. This high resolution is also useful in studying large macromolecules such as proteins with multiple charges, which can be produced by electrospray ionization. For example, attomole level of detection of two peptides has been reported. These large molecules contain a distribution of isotopes that produce a series of isotopic peaks. Because the isotopic peaks are close to each other on the m/z axis, due to the multiple charges, the high resolving power of the FTICR is extremely useful. FTICR-MS is very useful in other studies of proteomics as well. It achieves exceptional resolution in both top-down and bottom-up proteomics.
Data loggers typically have slower sample rates. A maximum sample rate of 1 Hz may be considered to be very fast for a data logger, yet very slow for a typical data acquisition system. Data loggers are implicitly stand-alone devices, while typical data acquisition systems must remain tethered to a computer to acquire data. This stand-alone aspect of data loggers implies onboard memory that is used to store acquired data. Sometimes this memory is very large to accommodate many days, or even months, of unattended recording. This memory may be battery-backed static random access memory, flash memory, or EEPROM. Earlier data loggers used magnetic tape, punched paper tape, or directly viewable records such as "strip chart recorders". Given the extended recording times of data loggers, they typically feature a mechanism to record the date and time in a timestamp to ensure that each recorded data value is associated with a date and time of acquisition to produce a sequence of events. As such, data loggers typically employ built-in real-time clocks whose published drift can be an important consideration when choosing between data loggers. Data loggers range from simple single-channel input to complex multi-channel instruments. Typically, the simpler the device the less programming flexibility. Some more sophisticated instruments allow for cross-channel computations and alarms based on predetermined conditions. The newest data loggers can serve web pages, allowing numerous people to monitor a system remotely.
=== In the United Kingdom === Based on Appert's methods of food preservation, the tin can process was allegedly developed by Frenchman Philippe de Girard, who came to London and used British merchant Peter Durand as an agent to patent his own idea in 1810. Durand did not pursue food canning himself, selling his patent in 1811 to Bryan Donkin and John Hall, who were in business as Donkin Hall and Gamble, of Bermondsey. Bryan Donkin developed the process of packaging food in sealed airtight cans, made of tinned wrought iron. Initially, the canning process was slow and labour-intensive, as each large can had to be hand-made, and took up to six hours to cook, making canned food too expensive for ordinary people. The main market for the food at this stage was the British Army and Royal Navy. By 1817, Donkin recorded that he had sold £3000 (equal to £222,201 today) worth of canned meat in six months. In 1824, Sir William Edward Parry took canned beef and pea soup with him on his voyage to the Arctic in HMS Fury, during his search for a northwestern passage to India. In 1829, Admiral Sir James Ross also took canned food to the Arctic, as did Sir John Franklin in 1845. Some of his stores were found by the search expedition led by Captain (later Admiral Sir) Leopold McClintock in 1857.
Sources: en.wikipedia.org
Luteinizing hormone is available mixed with FSH in the form of menotropin, and other forms of urinary gonadotropins. More purified forms of urinary gonadotropins may reduce the LH portion in relation to FSH. Recombinant luteinizing hormone is available as lutropin alfa (Luveris).
When the rats were exposed to a bacterial substance that should induce keratitis of the cornea, the amount of inflammation in the treatment group of rats (received the eye drops after exposure) was inhibited. Magnetic nanoparticles have also been used in hyperthermic therapy of cancer, cell purification, biosensing, and immunocytochemical tests.
=== Secondary ion mass spectrometry (SIMS) procedure === In case of measuring the hydration rim using the depth profiling ability of the secondary ion mass spectrometry technique, the sample is mounted on a holder without any preparation or cutting. This method of measurement is non-destructive. There are two general SIMS modes: static mode and dynamic mode, depending on the primary ion current density, and three different types of mass spectrometers: magnetic sector, quadrupole and time-of-flight (TOF). Any mass-spectrometer can work in static mode (very low ion current, a top mono-atomic layer analysis), and dynamic mode (a high ion current density, in-depth analysis). Although relatively infrequent the use of SIMS on obsidian surface investigations has produced great progress in OHD dating. SIMS in general refers to four instrumental categories according to their operation; static, dynamic, quadrupole, and time-of-flight, TOF. In essence it is a technique with a large resolution on a plethora of chemical elements and molecular structures in an essentially non destructive manner. An approach to OHD with a completely new rationale suggests that refinement of the technique is possible in a manner which improves both its accuracy and precision and potentially expands the utility by generating reliable chronological data. Anovitz et al. presented a model which relied solely on compositionally-dependent diffusion, following numerical solutions (finite difference (FD), or finite element) elaborating on the H+ profile acquired by SIMS.
Sources: en.wikipedia.org
Although no cure for multiple sclerosis has been found, several therapies have proven helpful. Several effective treatments can decrease the number of attacks and the rate of progression. The primary aims of therapy are returning function after an attack, preventing new attacks, and preventing disability. Starting medications is generally recommended in people after the first attack when more than two lesions are seen on MRI. The first approved medications used to treat MS were modestly effective, though were poorly tolerated and had many adverse effects. Several treatment options with better safety and tolerability profiles have been introduced, improving the prognosis of MS.
=== Techniques === There are four major methods used to quantify the metabolome of single cells; they are: fluorescence–based detection, fluorescence biosensors, FRET biosensors, and mass spectroscopy. The first three methods listed use fluorescence microscopy to detect molecules in a cell. Usually these assays use small fluorescent tags attached to molecules of interest, however this has been shown be too invasive for single cell metabolomics, and alters the activity of the metabolites. The current solution to this problem is to use fluorescent proteins which will act as metabolite detectors, fluorescing whenever they bind to a metabolite of interest. Mass spectroscopy is becoming the most frequently used method for single cell metabolomics. Its advantages are that there is no need to develop fluorescent proteins for all molecules of interest, and is capable of detecting metabolites in the femtomole range. Similar to the methods discussed in proteomics, there has also been success in combining mass spectroscopy with separation techniques such as capillary electrophoresis to quantify metabolites. This method is also capable of detecting metabolites present in femtomole concentrations. Another method utilizing capillary microsampling combined with mass spectrometry with ion mobility separation has been demonstrated to enhance the molecular coverage and ion separation for single cell metabolomics. Furthermore, direct infusion mass spectrometry, so call-ed live-single cell mass spectrometry, has also been successfully performed on human cells.
Pinoline, also known as 6-methoxytryptoline or as 6-methoxy-1,2,3,4-tetrahydro-β-carboline (6-MeO-THβC), is a β-carboline long-claimed to be produced in the pineal gland during the metabolism of melatonin, however its pineal occurrence remains controversial. Its more common name is a contraction of "pineal β-carboline". The biological activity of this molecule is of interest as a potential free radical scavenger, also known as an antioxidant, and as a monoamine oxidase A inhibitor.
== Causes == As with other eating disorders, binge eating is considered an "expressive disorder": a disorder that is an expression of deeper psychological problems. People who have binge eating disorder have been found to have higher weight bias internalization, which is characterized by low self-esteem, unhealthy eating patterns, and body dissatisfaction. Binge eating disorder commonly develops as a result of or side effect of depression, as it is common for people to turn to comfort foods when they are feeling down. There was resistance to granting binge eating disorder the status of a fully fledged eating disorder because many perceived binge eating disorder to be caused by individual choices. Previous research has focused on the relationship between body image and eating disorders, and concludes that disordered eating might be linked to rigid dieting practices. In the majority of cases of anorexia, extreme and inflexible restriction of dietary intake leads at some point to the development of binge eating, weight regain, bulimia nervosa, or a mixed form of eating disorder not otherwise specified. When under a strict diet that mimics the effects of starvation, the body may be preparing for a new behavioral pattern, one that involves consuming a large amount of food in a relatively short period of time. Some studies show that BED aggregates in families and could be genetic. However, very few published studies of the genetics of BED exist. Research suggests that environmental factors and the impact of traumatic events can precipitate binge eating disorder.
Sources: en.wikipedia.org
Legality depends on the country and the intended use. In many places it is not approved as a medicine and may be sold only as a research chemical. Importation or possession can be restricted, and sports organizations prohibit it.
Anti-doping laboratories typically use LC-MS/MS to detect SR9009 or its metabolites in urine or blood. The exact assay depends on the laboratory and the testing program. Detection can be challenging because the compound may be rapidly metabolized and present at low levels.
Stenabolic is an informal nickname used in online fitness and research-chemical markets, not an official drug name. It likely references reported effects on endurance in rodent studies. The nickname does not imply approval or proven human benefit.
Legality depends on the country and the intended use. In many places it is sold as a research chemical, but sports and medicine regulations restrict it.